Description: 3 Attempt Automatic Generator Control Module AECM107with wireless/wired/local start/stop functionSuitable for single and three phase generators.Not suitable for petrol generators with manual choke. DESCRIPTION The Model AECM107 is an Automatic Generator Control Module designed to automatically [remotely] or manually start and stop the engine. It will indicate the operational status and fault conditions, automatically shut down the engine and indicate the start engine failure by flashing "START FAIL" LED on the front panel. Other faults are indicated by steady LEDOperation of the module is via 2 pos. toggle switch mounted on the front panel with OFF-ON positions (Local Control).Wired remote control of the module is via terminal 1. Wireless control of the module is via key fob (supplied). WIRED REMOTE / LOCAL CONTROLFor wired remote control: toggle switch is in “OFF” position; remote start [input 1] is linked to battery negative; For local control: front switch is in “ON” position; [input 1] is unused. 0.5 Second after the fuel relay is energized [terminal 5], the 3 attempt start will begin its start sequence: the start relay will energize, feeding battery +ve (on terminal 7 to terminal 2 and thence on to the start circuit. If the engine has not fired by the end of 1st attempt, the starter is turned off for a resting period. The sequence will then repeat up to a maximum number of start attempts. Following a successful start, sensed when AC alternator's voltage rises above 40% of nominal, the start relay is de-energized and latched out to prevent reengagement of the starter with the engine running. WIRELESS CONTROLToggle switch is in OFF position. Terminal 1: (wired remote start is unused) Make sure there are no metal doors/walls/other metal shields between you and controlled generator. Any metal obstacle can significantly reduce the working distance between the transmitter (key fob) and controlled generator. Press "A" button on a key fob for 1 sec and release it. The generator should try to start within a few seconds. Press "B" button to stop the set. If your generator doesn't respond - try to come closer to controlled generator. PRE-HEAT CONTROL (optional, not included)For wired remote start: toggle switch is in “OFF” position, pre-heat enabler [DIP switch 2] is ON, remote start [input 1] is linked to battery negative;For local start: pre-heat enabler [DIP switch 2] is ON, toggle switch is in “ON” position;For wireless start: toggle switch is in “OFF” position, pre-heat enabler [DIP switch 2] is ON, remote wired start [input 1] is unused;When 10 second pre-heating cycle is timed out and flashing LED on the panel is turned off, the module will begin its start sequence: the fuel solenoid relay is energised feeding battery +ve on terminal 7 to terminal 5 and thence to the fuel solenoid circuit, the start relay will energise, feeding battery +ve on terminal 7 to terminal 2 and thence on to the start circuit. If the engine has not fired by the end of 1st attempt, the starter is turned off for a resting period. The sequence will then repeat up to a maximum number of start attempts. Following a successful start, sensed when AC alternator's voltage rises above 40% of nominal, the crank relay is de-energised and latched out to prevent re-engagement of the starter with the engine running. LOAD CONTROL (optional, not included)After a successful start, when engine's parameters are settled (when 7 sec time delay provided by hold-off timer is timed out), the Load Control Output will energize and send a signal from terminal 10 to an external power relay. This energizes a contactor which will connect the AC alternator output to the load. The run time before accepting load and the run time after relieving load (while generator is still running and is ready to accept the load again if the remote/local start signal is switched back on) are reprogrammable with a limit of 255 sec [4.25 min] max.(for each timer).Should the engine still fail to start after the maximum number of attempts, START FAIL is displayed and the starter is latched out until reset via “OFF” position of toggle switch or via terminal 1 / key fob if the engine start was initially made via remote start signal. NOTEThe starter relay can only energize for 2nd and 3rd crank cycle if “Low Oil Pressure” is sensed, to confirm that the engine is stationary. This is designed to prevent damage to the starter and ring gear in the event of the control module not sensing that the engine has started (i.e. terminals 11 and 12 are not connected properly to the alternator AC output). Should the engine still fail to start after the maximum number of attempts, “START FAIL” is displayed and the starter is latched out until reset via “OFF” position of toggle switch or via terminal 1 if the engine start was initially made via remote start signal. Relay outputs are provided for: Fuel Solenoid outputStarter motor outputPreheat output (optional, not included)Load control output (optional, not included) The relays supply positive plant supply out. Configurable inputs are available for: Low Oil Pressure.High Engine Temperature.Wired Remote Start.AC alternator monitor.Emergency Stop input [N/O switch] to give protection expansion.Pre-heat mode enabler (optional) Multiple alarm channels are provided to monitor the following: Under/Over speed (speed fault) This sensor can be enabled / disabled via DIP switch 1Low oil pressureHigh engine temperatureFail to StartEmergency stop button status The AECM107 series modules have been designed for DIN rail and/or flat surface panel mounting. Wiring diagram AECM107 SPECIFICATION DC Supply (engine starting battery): 12V or 24V ( 8...40Vdc )Max. Standby Current: 10 mA @ 12 VAlternator Input Range: 300 VAC maxUnder speed shutdown: @ 30 Hz [45Hz for USA and Canada]Over speed shutdown: @ 57 Hz [69Hz for USA and Canada]Number of attempts: 3Crank duration: 12 sec (max.) self-regulatedPreheat time: 10 sec (optional)Load on time delay: 10 sec (optional)Load off time delay: 10 sec (optional)Hold-off timer set for: 7 secStarter output (terminal 2): 20A maxFuel output (terminal 5): 20A maxPre-heat output (terminal 9): 20A max (optional)Load control output (terminal 10): 20A max (optional)Dimensions: 95 X 90 X 40 mm (exc. flanges)Operating Temperature Range: -30 to +70°C.For internal use only.All settings are user-configurable prior to shipment. WIRELESS KEY FOB/RECEIVER CHARACTERISTICS Working frequency: 433MhzReceiver sensitivity:>-105dBEncoding type: fixed codeMax. working distance (in open space) up to 100m (not guaranteed)Battery not included, please fit type 23A battery. All optional inputs / outputs available at extra cost, please contact us if you need a pre-heat function, battery voltage sensor (BVS) or load control output. Package Includes: 1x AECM107 controller with wireless receiver built-in1x Transmitter (key fob) comes without battery, please fit type 23A 12V battery1x Wiring diagram/manualThe DIN rail is not included
Price: 125 USD
Location: Rowley Regis
End Time: 2024-02-21T19:04:12.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: GenControl
MPN: AECM107
Country/Region of Manufacture: United Kingdom